本人看有關4mx電池的文章說x360 x365的機器會自動屏蔽故障卡 本人e文不好 不知道到底怎麽囘事兒 ServeRAID battery failures and their effect on host systems - Servers RETAIN tip: H18443
Additional information There are different ways in which systems behave when the battery is approaching its end of usable life. In many cases, the battery no longer charges to its specified voltage as it reaches the end of its usable life. This is detected by the ServeRAID controller and an alert is generated by the ServeRAID Manager to indicate that the FRU battery needs to be replaced. In other cases, as the battery fails, the charging circuit on the ServeRAID controller draws a short current surge from the PCI/PCI-X Slot. The PCI/PCI-X current-limiting circuit on some servers, like the xSeries 360 and xSeries365, turns off power to the PCI Slot and the controller is no longer seen at POST. This behavior can be confirmed by watching the controller in the Slot at power on. The Slot powers up, indicated by the green power LED, then shortly after, powers off with the amber warning LED lit. On systems without PCI-X "current limiting" circuitry, the controller may return a "controller failure" or "battery failure" message during POST, depending on the status of the battery.