Study RBCM: 7B7-01-01 B0 B1 B2 B3 B4 B5(checksum) in HEX B1 - it is (in BIN): b7 - 0 or 1 = 0 - no auto door lock or 1 - auto door lock (activates door lock function in RBCM) b6 - 0 or 1 = function is not known b5 - 0 or 1 = function is not known b4 - 0 or 1 = function is not known b3 - 0 or 1 = 0 - 1x blinker when doors close from remote control or 1 - no blinker when doors close from remote control b2 - 0 or 1 = function is not known b1 - 0 or 1 = 0 - no blinker when doors open from remote control or 1 - 3x blinker when doors open from remote control (w/alarm system) b0 - 0 or 1 = function is not known B4 - it is (in BIN): b7 - 0 or 1 = function is not known b6 - 0 or 1 = 0 - OFF 1 - ON (ability to lock doors when Ignition ON) tested on CX5 b5 - 0 or 1 = function is not known b4 - 0 or 1 = function is not known b3 - 0 or 1 = 0 - OFF 1 - ON (ability to lock doors when doors open) tested on CX5 b2 - 0 or 1 = function is not known b1 - 0 or 1 = function is not known b0 - 0 or 1 = function is not known
ability to lock doors when Ignition ON tested on CX5