• 2

拿到疑似他人退貨的機子真不開心

摁摁摁卸卸各位大大的意見噢:)
小妹我已經不想去追究了,
對於華碩直營店實在心冷,
奉勸大家台南北門的連鑫電腦不要去啊!
店員後來的態度實在差到爆
哀哀哀
整件事情就這樣落幕吧
反正最後的輸家依然是消費者
我想應該是要HD支援 SMART 才看的到一些數值
現在 HD 應該都有 support ,但不是所有的
smart attr 都有。
建議找個 smart 軟體,應該可以看到,
windows 的我不熟,linux 可以用以下 cmd

smartctl -a /dev/sda

=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar 7K1000
Device Model: Hitachi HDS721075KLA330
Serial Number: GTG200P8G0GJGC
Firmware Version: GK8OA70F
User Capacity: 750,156,374,016 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1
Local Time is: Thu Sep 25 11:52:57 2008 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (11471) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 191) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
2 Throughput_Performance 0x0005 100 100 054 Pre-fail Offline - 0
3 Spin_Up_Time 0x0007 110 110 024 Pre-fail Always - 544 (Average 545)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 752
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 4074
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 111
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 855
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 855
194 Temperature_Celsius 0x0002 176 176 000 Old_age Always - 34 (Lifetime Min/Max 22/74)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
  • 2
內文搜尋
X
評分
評分
複製連結
Mobile01提醒您
您目前瀏覽的是行動版網頁
是否切換到電腦版網頁呢?